Showing posts with label techie. Show all posts
Showing posts with label techie. Show all posts

Thursday, November 12, 2009

Latest acquisition by HP

Hewlett-Packard Plans to Buy 3Com for $2.7 Billion

By Connie Guglielmo and Rochelle Garner

Nov. 11 (Bloomberg) -- Hewlett-Packard Co., the world’s biggest personal-computer maker, plans to buy 3Com Corp. for $2.7 billion, stepping up competition with Cisco Systems Inc. in the computer-networking market.

3Com shareholders will receive $7.90 a share in cash, 39 percent more than today’s closing price, Palo Alto, California-based Hewlett-Packard said in a statement. The transaction is expected to close in the first half of next year, Hewlett-Packard said.

Chief Executive Officer Mark Hurd is seeking to add to Hewlett-Packard’s $118 billion in annual sales, expanding into markets that offer higher profit margins than printers or personal computers. Hewlett-Packard did a “full search” of networking companies and selected 3Com partly because of its presence in China, said Dave Donatelli, executive vice president and general manager for servers and networking.

“They get a huge beachhead in China, that’s first and foremost,” Greg Mesniaeff, an analyst with Needham & Co., said in an interview from New York. 3Com also “has some success building momentum outside of China,” he said.

Hewlett-Packard also reported profit, excluding some items, of $1.14 a share in the fiscal fourth quarter. That topped the average estimate of $1.11 in a Bloomberg survey. Sales fell 8 percent to $30.8 billion. Analysts had estimated $29.8 billion.

First Quarter

For the first quarter, revenue will be $29.6 billion to $29.9 billion, and earnings will total $1.03 to $1.05 a share, Hewlett-Packard said. Analysts predicted sales of $29.2 billion and earnings of $1.03 a share.

Hewlett-Packard fell as much as 65 cents to $49.35 in extended trading after closing at $50 on the New York Stock Exchange. The shares have gained 38 percent this year through the NYSE close.

3Com surged as much as $2.03, or 36 percent, to $7.72 in late trading after closing at $5.69 on the Nasdaq Stock Market. The stock has more than doubled this year.

Hewlett-Packard also boosted its sales and profit forecasts for 2010. For the year, revenue will be $118 billion to $119 billion, up from a previous prediction of as much as $118 billion. Earnings will be $4.25 to $4.35 a share, more than a previous forecast of as much as $4.30. Analysts predict sales of $118.1 billion and profit of $4.25 a share.

Data Centers

Adding 3Com increases competition with San Jose, California-based Cisco, the world’s largest networking company. Earlier this year, Cisco expanded into Hewlett-Packard’s turf of the corporate data center -- vast rooms of computers that store company files, transmit information and run vital business applications.

“It makes H-P well-positioned to rival Cisco in the data center,” said Vanessa Alvarez, a Boston-based analyst with research firm Frost & Sullivan. “It gives H-P an enterprise customer installed base.”

Hurd, 52, said in March at an investor conference that Hewlett-Packard will take a “disciplined” approach to acquisitions. The company has bought more than 30 companies since he took over as CEO in 2005. Hewlett-Packard already expanded its computer-services business last year with the $13.2 billion takeover of Electronic Data Systems.

“By joining 3Com with Hewlett-Packard, we have created the No. 2 networking company,” Donatelli said in an interview. “Customers have been frustrated by the fact that their networks have been proprietary, they’ve been slow to change, they’ve been very high cost relative to other things they buy.”

3Com, based in Marlborough, Massachusetts, has 2,400 engineers in China who will join Hewlett-Packard to work on research and product development, Donatelli said.

Chinese Sales

3Com gets about half of its revenue from sales in China, the byproduct of a joint venture it since ended with Huawei Technologies Co. The company has been working to expand to corporate customers outside of China, using lower-cost products as a wedge to counter Cisco.

Both 3Com and Cisco make routers and switches, devices that direct network traffic. Large companies typically buy switches to transmit data. Phone carriers tend to purchase routers, which are more expensive.

“Cisco is very confident in our business strategy, commitment to product innovation and ability to provide strategic business value to our customers in a highly competitive marketplace,” Terry Alberstein, a spokesman for Cisco, said in an e-mailed statement.

No. 2

3Com was second to Cisco in the market for computer networking equipment before its sales spiraled down starting in the late 1990s. The company recorded revenue of $5.6 billion in 1997 and less than half that four years later, after the bursting of the technology bubble. Cisco rebounded, taking sales from competitors such as 3Com, and is more than four times bigger than it was in 1998.

In 2003, 3Com left Silicon Valley, moving to Massachusetts from Santa Clara, California. The company owned the naming rights to the home stadium of the National Football League’s San Francisco 49ers between 1996 and 2002.

Robert Mao became CEO in April 2008, replacing Edgar Masri, a month after a previous takeover agreement was thwarted. 3Com had agreed in September 2007 to be bought for $2.2 billion by Huawei and private-equity firm Bain Capital LLC. The deal was withdrawn after some U.S. lawmakers said it would put 3Com’s anti-hacking technology, used by the Defense Department, in Chinese hands.

The company now has a new product line, based on switches and routers it sold to China, and in September reported its first sale to a data center outside of China.

‘Undervalued’ Company

“3Com is perhaps the most undervalued company in the networking space,”Zeus Kerravala, an analyst with Boston-based research firm Yankee Group, said in an e-mail. “It has the broadest enterprise portfolio of any company except Cisco.”

Shares of Brocade Communications Systems Inc., the largest maker of networking gear that connects storage computers, fell as much as 7 percent to $8.60 in late trading. Investors had speculated that Hewlett-Packard would buy Brocade after the Wall Street Journal said last month the company was shopping itself.

Morgan Stanley advised Hewlett-Packard on the deal, and Cleary Gottlieb was the company’s counsel. Goldman Sachs Group Inc. advised 3Com

Thursday, October 29, 2009

How to obtain SPcollects

The following is the procedure for SPCollects on a Clariion, CX, CX3 and CX4 machines.

If you are running release 13 and above, you will be able to perform the SP Collects from the GUI of Navisphere Manager Software.

Using Navisphere perform the following steps to collect and transfer the SPCollects to your local drive.

  1. Login to Navisphere Manager
  2. Identify the Serial number of the array you want to perform the SP Collects on
  3. Go to SP A using expand (+)
  4. Right click on it and from the menu, select SPCollects
  5. Now go to SP B in the same array
  6. Right click on it and from the menu, select SPCollects
  7. Wait for 5 to 10 minutes depending on the how big your array is and how busy your array is
  8. Now right click on SP A and from the menu select File Manager
  9. From the window, select the zip file SerialNumberOfClariion_spa_Date_Time_*.zip
  10. From the window, hit the transfer button to transfer the files to your local computer.
  11. Follow a similar process ( 8, 9, 10) for SPB, from the File Manager
  12. The SP B file name will be SerialNumberOfClariion_spb_Date_Time_*.zip

For customers that do not have SPCollects in the menu (running release 13 below), there is a manual way to perform SPCollects using Navicli from your management console or an attached host system.

To gather SPCollects from SP A, run the following commands

navicli –h xxx.xxx.xxx.xxx spcollect –messner

Wait for 5 to 7 mins

navicli –h xxx.xxx.xxx.xxx managefiles –list

The name of the SPCollects file will be SerialNumberOfClariion_spa_Date_Time_*.zip

navicli –h xxx.xxx.xxx.xxx managefiles –retrieve

where xxx.xxx.xxx.xxx is the IP Address of SP A

For SP B, similar process like above, the name of the file you will be looking for is SerialNumberOfClariion_spb_Date_Time_*.zip

Where xxx.xxx.xxx.xxx will be the IP Address of SP B

SPCollects information is very important with troubleshooting the disk array and will give the support engineer all the necessary vital data about the storage array (environment) for troubleshooting.

The following data that is collected using the SP Collects from both the SP’s:

Ktdump Log files

iSCSI data

FBI data (used to troubleshoot backend issues)

Array data (sp log files, migration info, flare code, sniffer, memory, host side data, flare debug data, metalun data, prom data, drive meta data, etc)

PSM data

RTP data (mirrors, snaps, clones, sancopy, etc)

Event data (windows security, application and system event files)

LCC data

Nav data (Navisphere related data)

Regards,

MARK

How to change Clariion SP IP address

When you initially install a new storage system, you must run the Navisphere Storage System Initialization Utility which prompts you to configure IP addresses for the SPs and set up accounts to log in to the SPs. You use these IP addresses when you connect and log into Navisphere Manager.

For an existing storage system that has been installed, initialized, configured, and possibly used, you must use Navisphere Manager to change the IP address of an SP.

IMPORTANT: Before you change the IP address of an SP, if the storage system is on a domain, you must remove that storage system from the domain. When you enter a new IP address and accept the acknowledgments to change the address, you will be disconnected and the SP will reboot. You will then need to log onto the SP using the new address and add the storage system to a domain. If the storage system was the domain Master, when you re-connect, you will need to either recreate the domain and become master or else join another domain.

Dont forget to create the PPP Dialup Connection before attempting to login to the SP, otherwise it will fail

1. Open Navisphere Manager.

2. If the storage system is in a domain, remove it from the domain.

3. Under the Storage tab, click and expand the icon for the storage system that you want to modify.

4. Right-click the SP whose IP address you want to change and select Properties.

5. Click the Network tab.

6. Enter the new IP address in the IP Address field.

7. Click Apply to apply the change.

Note: If you have not removed the SP from the domain, you will see a prompt that strongly suggests that you cancel the operation and remove the SP from the domain before changing the SP’s IP address. Click either Yes to continue or No to cancel the address change.
8. At the confirmation prompt, click Yes to continue or No to cancel the IP address change.

9. At the second confirmation prompt, click Yes to continue or No to cancel the IP address change.

Note: Either Navisphere Manager will fail over to the unchanged SP, or the Navisphere Manager session will disconnect. In either case, the changed SP will reboot and will be available at the new IP address.
10. If Navisphere manager did not fail over to the unchanged SP, log into Navisphere Manager on either SP, noting that the changed SP has the new address.

11. Add the storage system to an existing domain or if necessary, create a new domain with the SP as master. See Help in Navisphere Manager.

Note: For further information on using Navisphere Manager, click Help in Navisphere Manager

Credit to author= unknown

Regards,
MARK

Wednesday, August 12, 2009

How to configure zoning on MDS Cisco SAN Switch

Let’s start this post by a confession, as I'm a Cisco enthusiast I’ll be slightly biased towards Cisco products be it an Ethernet Switch, SAN switch or Multiprotocol Gateway, I always have and will always be in favor of their products far and above their competitor offerings even Brocade's. Although over here in Malaysia, Brocade is arguably the most dominant player or the default choice among majority of companies, my personal favorite will always be Cisco MDS series. It might be a daunting task or overwhelming for a person who doesn’t have any experience in configuring Cisco Ethernet Switch to dive straight into MDS as it has hierarchical level or privilege to execute command unlike Brocade's, Cisco IOS has proven to be easier and flexible to be configured with - well at least from my point of view! Let’s dive straight into the configuration portion using CLI:

Assuming that the IP address for the Management Port is already configured, let's try to telnet to the SAN switch by executing:

# telnet 10.127.38.150

Configure the switch name by:

#switchname dev_mds9120_swA

Verify the name changes made:

# show switchname

Moving on to sub-configuration mode and let’s configure all ports connected to hosts and array to auto-negotiating speed:

# config

#interface fc1/2,fc1/3,fc1/15,fc1/6

#switchport speed auto

# no shutdown

#exit

What I'm doing is essentially configuring all the interface in this case interface fc1/2 , fc1/3, fc1/15 and fc1/6 to auto-negotiate the speed and enable the interface by issuing no shutdown. You can refer which port is connected to which hosts or array by issuing show fcns database, show interface brief or by looking at the topology in Fabric Manager.

Let’s go to interface fc 1/10 and fc1/11 to configure ISL:

#interface fc1/10,fc1/11

#switchport trunk allowed

#no shutdown

#exit

We will then configure Domain ID of 1 on the default VSAN (1):

#fcdomain domain 1 static vsan 1

#exit

Verify the Domain ID is correct:

#show fcdomain vsan 1

Don't forget to save the running config to NVRAM:

#copy running-config startup-config

Show the name server database and copy the content to text file to avoid any typo:

#show fcns database

Zone the Unix server to the array in this case the Solaris 10 server to Symmetrix array, by creating a zone:

#config

#zone name Sol10_hba1_Symm_1 vsan 33

#member pwwn 210000e08b90e795

#member pwwn 50060160082006e2

#end

What I'm doing is creating a zone for a single port HBA on the Solaris server and for the first storage array port on the Symmetrix. Repeat the steps above until all zone is created for every initiator and every target and verify the config:

#show zone vsan 33

Create a zoneset with a suitable name. A zoneset is a collection of all zones in the SAN fabric:

#config

#zoneset name Unix_Symm_MDS9120 vsan 33

Add zones to the zoneset:

#member Sol10_hba1_Symm_1

Repeat the step above for all zone members in the zoneset and verify the zoneset is in accordance to your plan before activation:

#end

#show zoneset vsan 33

#config

#zoneset activate name Unix_Symm_MDS9120 vsan 33

#exit

Verify your config and save it:

#show zoneset active vsan 33

#copy running-config startup-config

#exit

That's all for today peeps, easy right? In a later edition we will look at the nitty-gritty of configuring an Inter-switch link. Maybe we will than look at configuring either Clariion, Symmetrix, USP, EVA or MSA storage using CLI before we can complete our make believe SAN. I'm familiar with NTAP and certain IBM storage as well but I'll leave that to the expert, let's focus on either EMC, HDS or HP array as that's what I'm comfortable working with. Please refer to any good article on how to decipher and translate Symmetrix or HDS USP WWN to disk adapter or disk director from the net.

Any questions?

Regards,

MARK

Tuesday, June 16, 2009

Restoring Exchange 2003 and Exchange 2007 data using the recovery storage group

The Recovery Storage Group (RSG) feature in Exchange Server 2003 and Exchange Server 2007 lets you to mount a second copy of an Exchange mailbox store on any Exchange server in the same Exchange Administrative Group as the original while the original store is still running and serving clients. This allows you to recover data from an older backup copy of the store without disturbing client access to current data. See your Microsoft Exchange documentation for instructions on creating the recovery storage group and adding the mailbox stores you want to restore to it.

After the RSG is created and one or more stores are added to it, you can restore online backup sets to it. Then you can use the version of the EXMerge utility in Exchange 2003 and Exchange 2007 to extract mailbox data from the stores into .PST files, and optionally merge the extracted data back into the online stores.

If the RSG resides on a different Exchange server than the databases you are restoring, you should review the requirements for redirecting the restore of Exchange storage groups.

Following are requirements for restoring Exchange Server 2003 and Exchange Server 2007 data using the Recovery Storage Group (RSG):

  • Data cannot be restored from a snapshot backup (Exchange 2003 only).

  • If multiple stores are selected for restore, mailbox stores in the RSG must come from the same storage group. You cannot add mailbox stores from different storage groups to the RSG at the same time.

  • Public folder stores are not supported for restore using the RSG.

  • Do not mount mailbox stores in the RSG before the restore. If you do mount the stores before the restore, then you must dismount them. Select the following option on the database property page in Exchange System Manager:

    This database can be overwritten by a restore

    Then, delete any files created in the data path for the RSG and added stores prior to restoring them.

    Any files created in the data path for the RSG and added store or stores, should be deleted as well, if stores were mounted prior to the restore.

  • On the server that hosts the RSG, there must be a storage group with the same name as the original storage group for the data you are restoring. If no such storage group exists on the server, then you can use that name for the RSG when you create it.

  • The Active Directory topology of the Exchange system must be intact and in the same state it was in when the backup was made. You cannot restore mailbox stores that were deleted and recreated. In addition, you cannot recover mailboxes from stores if the mailboxes were deleted and purged from the system or moved to other servers or mailbox stores.

  • Only Exchange mailbox stores from Exchange 2000 Server with Service Pack 3 or later can be restored to the RSG. Restored mailbox stores are upgraded to the store version currently running on the RSG server.

  • When the RSG exists on a server, the mailbox stores that it contains are the only stores that can be restored on that server by default. Symantec recommends that you create the RSG only when you intend to recover data using it, and remove the RSG from the server after the data recovery is complete

    Source : Symantec

    Regards,

    MARK

Wednesday, June 10, 2009

Advantages of using dual port HBA

The key feature separating the dual port from the traditional single port cards or competing dual port cards is the complete separation of channels on one HBA. Because each port on the HBA has its own logic and Fibre Channel dedicated ASIC chipset, each port operates independently from the other. Adapter performance is never compromised and each port is separately configured. For example, one port of the HBA can be running in a loop environment, while the other port operates in a switched fabric or point-to-point configuration.

Source:JNI
Regards,

MARK

Tuesday, June 9, 2009

How to perform SAN switch zoning

Steps to Zone Brocade Switch:

   1. Plug in the FC Connector into an open port on the switch.
   2. Login to the server and verify the HBA connection. It should see the switch but not the storage device.
   3. Login to the Brocade Switch GUI interface. You’ll need Java enabled on your browser.

   4. Check the Brocade Switch Port.
         1. On the visual depiction of the switch, click on the port where you plugged in the FC connector.
         2. The Port Administration Services screen should pop up. You’ll need to enable the pop-up.
         3. Verify that the Port Status is “Online”. Note the port number.
         4. Close the Port Administration Services screen.

   5. Find the WWN of your new device
         1. Navigate back to the original GUI page.
         2. Select Zone Admin, an icon on the bottom left of the screen. It looks like two squares and a rectangle.
         3. Expand the Ports & Attaching Devices under the Member Selection List.
         4. Expand the appropriate port number. Note the attached WWN.

   6. Create a new alias for this device
         1. Click New Alias button
         2. Follow menu instructions

   7. Add the appropriate WWN to the alias
         1. Select your new device name from the Name drop down menu
         2. Expand the WWNs under Member Selection List
         3. Highlight the appropriate WWN
         4. Select Add Member

   8. Add the alias to the appropriate zone
         1. Select the Zone tab
         2. Select the appropriate zone from the Name drop down menu
         3. Select the appropriate alias from the Member Selection List
         4. Click Add Member

   9. Ensure that the zone is in Zone Config in the Zone Config tab
  10. Save your changes by selecting ZoningActions -> Enable Config
  11. Login back in to the server to verify. It should now see the storage devices.

Terminology

HBA - Host Bus Adapter, which in this case, refers to the Fibre Channel Card. In LAN networking, it’s analogous to an Ethernet card.

WWN - World Wide Name, a unique 8-byte number identifying the HBA. In Ethernet networking, it’s analogous to the MAC address.

FC Zone - Fibre Channel Zone, a partitioned subset of the fabric. Members of a zone are allowed to communicate with each other, but devices are not allowed to communicate across zones. An FC Zone is loosely analogous to a VLAN.

Credit to original author

Regards,
MARK

Monday, May 25, 2009

DiskXtender 6.1 Extended Drive Migration

Argh, I'm supposed to oversee the migration process of DiskXtender ED containing stubs and Metadata for one of the largest DiskXtender and Centera deployment at SEA. Searched through EMC powerlinkg and discovered 3 methods of migrating the stubs and metadata. Each options listed here has its own pros and cons that requires carefull planning and execution.


Option 1: Data-Export Procedure:

1) Ensure that all transaction-, move- and purge logs on the Old Extended Drive are flushed out

2) Disable move schedule and disable real-time moves
3) Create/map the disk that becomes the new ED
 
4) Perform a Meta Data Export (MDE) of the original ED to a network share folder.
 
5) Stop DX services and set it to manual start
6)
 Run Vol Id ((http://www.sysinternals.com/Utilities/VolumeId.html), change the vol-id and drive letter of the old ED to temporal values

7) Reboot

8) Run Volume ID tool (http://www.sysinternals.com/Utilities/VolumeId.html), and assign the new drive the Volume ID and drive letter that was previously assigned to the old Extended Drive. 
9) Reboot
10) Start the DX service, and set it to automatic start again
 
11) At this point, DX recognizes the new ED but with no data inside.
 
12) Perform a Mata-Data import done in 2 step to the new ED.

 

Deallocate media from one ED and reallocate to the new ED (See EMC KB article - esg74432)

 

====================================================================

Option 2: Using dxdmchk utility

Using dxdmchk utility (command line utility) to fetch the files back from the Centera and then run the clean switch to stripped migration information of the files. In order to run the clean switch, EMC Support will issue an access key.
 
Then remove the media from the media group and uninstall DX. Next, reinstall DX and reconfig DX on the new server
Then, use any 3rd party utility to copy the files frm old ED to the new ED on the new server

 

====================================================================

Option 3: File restore (Centera media)

 

During the migration, the Extended drive should be made inaccessible to users and processes.

 

1) Save out the EMC Registry. (HKLM\Software\EMC) and Registry Log folder (C:\Program Files\EMC\DiskXtender)

 

2) Run a full Meta Data Export and export the data to a network drive that is not the current Extended Drive, or the new drive.

 

3) Disable the DiskXtender Move Schedule. 

4) Disable the DX service (in windows services). Disable the DxSpy Driver, and DxSpy Recognizer Driver. Both of these drivers are located in Device Manager. Go to Computer Management > Device Manager. Select "Show hidden devices" from the "View" drop down menu. Next, expand "non-plug and play drivers" in the right hand tree view. You will see both drivers as listed above. 

 

5) Make note of the Volume ID and Drive Letter of your current Extended Drive and save this information. 

6) Power down the system, make the physical swap of the Extended Drive. 

 

7) Power the system back up.

 

8) Run Volume ID tool (http://www.sysinternals.com/Utilities/VolumeId.html), and assign the new drive the Volume ID that was previously assigned to the old Extended Drive.

 

9) Verify the drive letter for the new drive matches the Drive Letter for the old Extended Drive. If the drive letter is not the same, change the drive letter to match the drive letter for the old Extended Drive, using Disk Manager in Windows.

 

10) Reboot.

 

11) Verify volume ID for the new SAN drive is the same as the Volume ID for the old Extended Drive. Verify that the drive letter for the new drive is the same as the drive letter for the old Extended Drive.

 

12) Set the DxSpy and DxSpy Recognizer drivers back to startup type "Demand", as originally configured, and set the DX service to manual.

 

13) Create a folder at the root of the new Extended Drive called "EmailXtender".

NOTE: Step #13 will differ, depending on the Media Folder names in use for your particular system. Make sure to manually create any Media Folders in Windows Explorer, prior to starting the DiskXtender Service, as part of Step #13.


14) Reboot.
 

 

15) Create a file in the directory called "dx_EmcService.log". (Use this step if you have Centera Media) -- see EMC KB article esg 61046

 

16) Start the DiskXtender service. Verify the service starts successfully and the Extended Drive has an "Online Status". 

 

17) Run the File Restore task on EMC media. (Right click on the media in the DiskXtender Administrator, and choose "Edit Tasks" from the flyout menu. Choose the "File Restore" task from the drop down menu, and complete the wizard. This will re-populate the new Extended Drive with the file and directory structure of the old Extended Drive.

***You can also run Meta-Data Import instead of File Restores for this step*** 

 

18) Force a Drive Scan. Enable the DiskXtender Move Schedule. 

19) Verify existing migrated files can be accessed, and new files can be successfully written to media.

 

20) Stop the DiskXtender Service. Cut the file in the directory called "dx_EmcService.log" out of the directory and save it to another location. (Use this step if you have Centera Media)

 

21) Start the DiskXtender Service. Set the Startup type back to "Automatic".


Regards,


MARK